Features :
- Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.
- Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.
- Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
- Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring with user-friendly interface.
- Display with 2.8” (320×240) color TFT LCD and red and yellow highlight LED.
- Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.
- Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data.
- Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.
Performance :
- NIBP monitoring
- Measurement method: Oscillometry
- Measurement mode: manual/auto/continuous.
- Auto measurement interval: adjustable from 1 to 90 minutes.
- Resolution: 1mmHg.
- Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
- Self-check function.
- Overpressure protection: double protection for software and hardware.
Range :
- Adult:
- Systolic pressure: 40mmHg~270mmHg
- Mean pressure: 20mmHg~235mmHg
- Diastolic Pressure: 10mmHg~215mmHg
- Pediatric:
- Systolic pressure: 40mmHg~200mmHg
- Mean pressure: 20mmHg~165mmHg
- Diastolic Pressure: 10mmHg~150mmHg
- Neonatal:
- Systolic pressure: 40mmHg~135mmHg
- Mean pressure: 20mmHg~110mmHg
- Diastolic Pressure: 10mmHg~100mmHg
- Upper and lower limit of alarm.
SpO2 monitoring:
- Continuous real-time measuring.
- Adopt digital SpO2 technology, which has strong anti-interference capability.
- Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
- Standard finger-clip probe for adult , binding probe for neonatal is optional.
SpO2 Measuring:
- Range: 35%~100% (Resolution: 1%)
- Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
Pulse Rate Measuring:
- Range: 30bpm~250bpm(Resolution: 1bpm)
- Accuracy: ±2bpm or ±2%, whichever is greater.
Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Accessories :
- A power cord
- A power adapter
- A SpO2 probe
- An adult NIBP cuff
- An extending tube for blood pressure
Physical characteristic :
- Dimension for product: 190(L)×162(W)×240(H)mm
- Weight: 1.6kg
- Dimension for packaging: 402(L)×228(W)×320(H)mm.
Reviews
There are no reviews yet.