CSSD INDIA Logo
Medical Equipments
Medical Equipments
pexels-mart-production-7089017
pexels-pixabay-236380
Medical Equipments
pexels-mart-production-7089629
Medical Equipments
pexels-mart-production-7088530
previous arrow
next arrow
, ,

Drager Oxylog 3000 Ventilator CIE 1082

The Drager Oxylog 3000 is a transport ventilator that can provide high ventilation performance. The Oxylog system includes integrated capnography and non-invasive ventilation. It runs on a time-cycle that can monitor a wide range of ventilation modes, including VC-AC, VC-SIMV, San-CPAP, and PC-BiPAP.

The Oxylog 3000 is a non-invasive ventilation machine with advanced leak composition. the system can be used in a hospital setting, in the field for emergencies, and can be used in winged aircraft for both adult and pediatric patients.

Features:

  • High confidence during transport.
  • Wide range of ventilation modes and AutoFlow.
  • Integrated capnography.
  • Ready for pediatric patients.
  • Automatic altitude compensation (BTPS).
  • Intuitive user interface.
  • Advanced data export functionality.
  • Drager Oxylog 3000 Specifications

 

Specifications:

Dimensions:

  • Height: 7.2 In (18.4 cm)
  • Width: 11.4 In (29 cm)
  • Depth: 6.9 In (17.5 cm)
  • Weight (Including internal battery): 12.8 lbs (5.8 kg).

Display:

  • Technology: Electro-luminescence (EL).
  • Resolution: 240 x 128
  • Dimensions: 4.3 x 2.2 In (10.8 x 5.6 cm).

Wireless Network:

  • Standards: IEEE 802.11g, Wi-Fi compatible.
  • Frequency Range: 2.412 to 2.462GHz.

Ventilation Modes:

  • VC-CMV, VC-AC, VC-SIMV, SpnCPAP, PC-BIPAP.

Ventilation Settings:

  • Pressure support: in the ventilation modes VCSIMV, PCBIPAP and SpnCPAP.
  • Apnoea ventilation: in the ventilation mode SpnCPAP.
  • AutoFlow (optional): in the ventilation modes VC-CMV, VCAC and VC-SIMV.
  • NIV: in the ventilation modes: SpnCPAP (/PS), PC-BIPAP (/PS), VC-CMV /AF, VC-AC /AF and VC-SIMV/AF.
  • Ventilation Respiratory Rate.
  • 2 to 60 /min (VC-SIMV, PC-BIPAP).
  • 5 to 60 /min (VC-CMV, VC-AC).
  • 12 to 60 /min for apnoea ventilation.

General:

  • Tidal volume: VT 0.05 to 2.0 L; BTPS.
  • Ti / I:E: I:E or Ti configurable, for all ventilation modes.
  • Ventilation Time Tatio I:E: 1:100 to 50:1.
  • Inspiration Time Ti: 0.2 to 10 s.
  • Inspiratory Pressure Pinsp: PEEP +3 to +55 mbar.
  • O2 Concentration: 40 to 100 Vol.%.
  • PEEP / CPAP: 0 to 20 mbar.
  • Trigger Sensitivity (Flow Trigger): 1 to 15 L/min.
  • Pressures support Psupp: 0 to 35 mbar (relative to PEEP)
  • Slope (Pressure Rise Time): Slow, standard, fast.